DELONGHI Conditioner Penguin Error Flashtool. Error 5002: s_invalid_da_file

Errors sp Flash Tool and their solution. Errors SP Flash Tool and their solution S Storage Not Match 3182

Edition of the Windows registry manually in order to delete the errors of keys error 3182 is not recommended if you are not a PC service specialist. Errors made in editing the registry can lead to the inoperability of your PC and cause irreparable damage to your operating system. In fact, even one comma, set in the wrong place, may prevent computer loading!

In connection with such a risk, we strongly recommend using reliable registry tools such as Winthrster [uploaded] (developed by Microsoft Gold Certified Partner) to scan and fix any problems associated with error 3182. Using the cleaning of the registry [load]. You can automate the process of searching for damaged registry entries, links to missing files (for example, causing a mistake %% error_name %%) and non.working links within the registry. Before each scan, a backup is automatically created, which allows you to cancel any changes with one click and protects you from possible damage to a computer. The most pleasant thing is that elimination of registry errors [load] can sharply increase the speed and performance of the system.

Before you manually restore the Windows registry, it is necessary to create a backup, exporting part of the registry related to error 3182 (for example, Microsoft Access):

  • Click on the button to start.
  • Enter “Command” in the search bar. Not yet pressed !
  • Holding Ctrl-Shift keys on the keyboard, click Enter.
  • The dialog box for access will be displayed.
  • Click yes.
  • Black box opens with a blinking cursor.
  • Enter Regedit and click Enter.
  • In the registry editor, select a key associated with error 3182 (for example, Microsoft Access), which requires a backup copy.
  • In the menu file, select export.
  • In the list, save the folder in which you want to save a backup copy of the Microsoft Access key.
  • In the File Name, enter the name of the backup file, for example, “Microsoft Access Reserve Copy”.
  • Make sure that the value of the selected branch has been selected in the Export Range field.
  • Click to save.
  • The file will be saved with the extension.reg.
  • Now you have a backup copy of the register related to Microsoft Access.

The following steps with manual editing of the registry will not be described in this article, since with a high probability they can lead to damage to your system. If you want to get more information about editing the registry manually, please read the links below.

When linovo’s phone flash, the Smart Phone Flashtool program before the process starts or at a certain stage of the firmware, various errors may appear.As a result, we cannot complete the process and get a four.digit SP FlashTool

Decoding of frequently found errors:

(1003) s_com_port_open_fail problem with the port.

    This error arises if COM ports are disabled in your BIOS (despite the fact that in this case the COM port is virtual, and a physical USB is used, but when connecting the device, you simply will not see the equipment for which Preloader drivers are placed).A problem is possible in a USB cable (changing the firmware USB cable will help).Problems directly in the USB USB port (changing the USB port).
    The size of any part of the firmware exceeds the size of the space allotted to it (usually this is a nuclear unit or recovery).Also, this error sometimes appears when using “raw” versions of Flashtool, changing the version of the flastula will help
    An error in nature and orientation is similar to error 1003. Solutions need to be sought according to the same principle.Reduce recording speed in the program settings. Tab: Options. DA download all. Speed. Full Speed.Also, changing the version of the firmware to V5 can also help.

(1040) S_UnsupPorted_Operation Scatter File is not suitable for the phone. For example, the name contains 6592, and the phone is actually 6589

(2005) S_BROM_CMD_STARTCMD_FAIL on phrasing phras cases of error:

    When choosing downloads or dsp_bl, a checkbox is not installed on blocks. You need to use the right version of SPFT, for example V2.XXX for MT6573 phones, or turn off the DA Download All mode.When choosing downloads or dsp_bl, a checkbox is installed on the downloads. You need to remove the mark from these blocks! If these blocks must be flashed. Connect the phone in Bootrom mode.When choosing Readback, Format or MemoryTest. You should connect the phone in Bootrom.

(3001) S_DA_EXT_RAM_RORROR may be problems with connection.

(3013) S_DS_SOC_CHECK_FAIL is possible, in the window of the SP_Flash_Tool program, you do not have a daw on UBOOT. uboot. The operating system bootloader drivers to initialize the main equipment (display, processor, GPIO).Or in the line of the path there are Russian names of folders for example: D: \ firmware \ Firmware Lenovo K930 \

(3144) S_DA_EMMC_FLASH_NOT_FOUND Problem with iron or Scatter File is not suitable for the phone. For example, the name contains EMMC, and the phone is actually with MTD flash.

(3066) S_DA_HANDSET_INFO_NOT_FOUND occurs with automatic formatting, you need to try to set the formatting addresses.

(3036) S_DA_INVALID_RANGE SP Flash Tool PMT address on the flash of the device does not coincide with that in the Scatter file.

    The PMT block must be removed through the Format tab, and pour a new file from the Scatter file through the “Download” button and sp Flash Tool will write new data about the PMT block and others too.

(1003) s_com_port_open_fail

The problem with the port. Can arise if:. For example, you have a COM ports (at least in this case, the COM port here is virtual, and the physical USB, but when you turn it off, you just won’t see the equipment on which the Preloader drivers in the USB cable (changing the cable for firmware) is disconnected. in the USB port of the computer (helps the cable reconnecting to another port).

It occurs when the size of any part of the firmware exceeds the size of the space allotted to it (usually this is a nucleus or a recovery block). Sometimes it occurs on the “raw” versions of a flashtul, so a change of version of the firmware may help a change. It may occur when firming the wrong version of the firmware, for another amount of memory.

13 error sp Flash Tool

The FlashTool program is actively used by users who want to firm the firmware of their mobile equipment. The product allows you to increase the productivity of the device, to achieve support for new games. Despite the apparent simplicity of using this application, sometimes users have difficulty. Flashtool errors. the phenomenon is quite common, but the exit is. We have presented a table where frequently found inaccuracies that appear during the firmware on the device. Decryption of errors of flastula will help to understand how to eliminate them and use all the functions of the program.

In the process of firming Android devices using the SP Flash Tool program, errors periodically occur, which often takes a fairly large amount of time on the solution of which on their own.

For your informing and amenities, a selection of the most common errors with a detailed description and options for solving and eliminating them have been completed.

If you reflash any section of your Android smartphone, then you have a chance that you will encounter an error of 2005. This error occurs right before the start of the firmware, interrupting this process.The SP FlashTool program is created to flanching phones based on the Android operating system. She can be used on her own, at home. To work with this program, you only need a phone, cable, and a computer.

What is an error 2005 in SP FlashTool?

This problem appears if your computer cannot contact the phone. A possible cause of an error is likely to be a processor or battery malfunction. Next will be listed methods for solving errors 2005 in decreasing the probability of triggering.

Without a battery

As you understand from the name, this method consists in the firmware of your phone in the mode without a battery. When you remove the battery, the FlashTool program will change the firmware algorithms that may be suitable for your case, and the firmware will begin.Detailed instructions:

  • Remove the battery from your smartphone. I think you yourself will figure out how
  • Open the SP FlashTool program. Go to the settings through the program menu, or click the Ctrl Shift o hot key. Go to the General section. Connection. Select “W/O BATTERY” item. This item means “Whout Battle”, that is, “without a battery”.

If none of these blocks was chosen.

Perhaps you are using the wrong version of Flash Tool for your smartphone. You can find out the right version on specialized forums, such as 4PDA.

If one of these blocks was chosen.

Try connecting the phone in Bootrom mode. If you do not have to flash these sections, then remove ticks from them.

Smartphone connection with PC

Your USB cable is possible. Try several other cables to make sure of their performance. Even if it works when charging or when moving files, it can still not work when firmware.

Change USB port on your computer. Try all available ports. There are cases when only one port of all is suitable for firmware. Do not be lazy, even check the ports on the motherboard, behind your PC.

Errors

Error code name 1002 or 0x3ea1003 or 0x3EBDescription of the error 1003 and her solution is the problem with the port. For example, an error may appear if COM ports are disabled in BIOS. Even if the COM port is virtual, and physical USB. In this case, you will not see the equipment on which Preloader drivers are placed. The problem may be in the USB cable, in this case, replace the cable. If the USB computer is faulty, then you need to roll the cable into another port. Theoretically, it can occur in the URT USB port mode. The port was visible, it was chosen in the Flash Tool settings, the program recorded it in the Ini file, after which the system was overloaded with a disabled port, and immediately launched Flash Tool without choosing a port. When, after the passage of the red strip, up to 100% as a result of the firmware, the operations buttons again become available for pressing, but neither error message nor a window with a green circle will appear this error, or similar to it, the code of which is 1013. In this state, Flash Tool does not cover the COM port, and an attempt to start any operation again, retraining the device, will cause an error. If the program has passed into such an indefinite state, then you need to close it and start it again1011 or 0x3F3Description of the error 1011 and its solution arises if the size of one of the parts of the firmware exceeds the size of the space allotted to it. This is usually a block of nucleus or recovery. This error sometimes occurs on unfinished versions of Flash Tool. Replace the used version of the firmware1012 or 0x3F4Description of the error 1012 and its solution use the firmware more fresh version1013 or 0x3F5Description of the error 1013 and its decision error is similar to the error 1003. Solutions need to be sought according to the same principle. The change of the firmware version can help, or the firmware of the device with a disabled battery1018 or 0x3FADescription of the error 1018 and its solution use the firmware more fresh version1022 or 0x3FEDescription of the error 1022 and its solution use the firmware more fresh version1040 or 0x410Description of the error1040 and its solution Scatter File is not suitable for the device. For example, the file name contains version 6777, and the device version 65551041 or 0x411Description of the error 1041 and its decision must be moved to the tab Help, press Open Logs Folder and remove all logs. Go to the firmware folder and delete the file Checksum.ini2004 or 0x7D4Description of the error 2004 and her solution to the problem may consist in the version of the flashtul. Download the version at the end of which there is a design designation. An error may occur if many USB drivers for different devices are installed in the operating system. Use the program UsbdeView To delete the installed USB drivers and perform the firmware via Flash Tool. Can help connect the device with a clamped volume key or . If the above methods do not help, after an error appears, you must immediately close the window with an error and immediately press the button Download again2005 or 0x7D5Description of the error 2005 and its solution error may occur on MTD devices if when choosing a mode Download On the blocks Preloader or DSP_BL not installed check. It is necessary to use the right version of Flash Tool, for example V2.XXX for MT6573 phones, or turn off the DA Download All mode. When choosing a mode Download On the blocks of Preloader or DSP_BL, a checkbox is installed, it is necessary to remove it from these blocks. If these blocks must be flashed, then connect the phone in bootrom mode. When choosing Readback, Format or MemoryTest You need to connect the device in Bootrom. You can try to flash a device with a disabled battery2020 or 0x7e4Description of the error 2020 and her decision in the Flash Tool settings to be forcibly set the box, thereby indicating that the device is without a battery. After that, connect the device through the test, but already with the battery2035 or 0x7F3Description of the error2035 and her solution after pressing the button Download Connect the switched device off to the computer with previously clamped volume buttons3001 or 0xbb9Description of the error 3001 and its solution may be a mistake related to connecting. Check the cable, reconnect the cable to another USB port3012 or 0xbc4Description of the error 3012 and its solution is the problem associated with determining the flash memory of the device. Use another version of the firmware, t.to. As different versions released, information about the flash memory is updated. If the above version did not help, try to flash the device on another computer, t.to. There are problems that do not allow to correctly determine the memory on a particular machine3013 or 0xbc5Description of the error 3013 And its solution is possible that in the firmware settings Flash Tool do not cost a check Uboot. Uboot. The operating system and drivers bootloader to initialize the main equipment, such as the display, processor, GPIO. An error may occur if the line on which the program or firmware is located is Cyrillic or incorrect symbols, hieroglyphs in the line. It is permissible to post the program and the firmware file only along the way that consists of Latin characters completely. An example showing incorrect file placement: C: \ Users \ User \ Desktop \ Firmware \ Tablet firmware \3054 or 0xbeeDescription of the error 3054 and her decision use another version of the firmware. Try replacing the firmware version from the fifth to the third version3066 or 0xbfaDescription of the error 3066 and its solution arises with automatic formatting. It is necessary to set the addresses of formatting manually3144 or 0xc48Description of the error 3144 and its solution error arises if there are problems with the hardware part of the device. It can also occur if the Scatter file does not fit the device. For example, the name contains EMMC, and the device is actually with MTD flash. There is a chance that the problem will be solved if you use another computer and operating system. It is preferable to use a computer with the Windows XP operating system with newly installed drivers3149 or 0xc4dDescription of the error 3149 and her decision use another version of the firmware. If you flash 3 versions, try 5 version, or vice versa. Select the mode Format All Download. It is necessary to reinstall the drivers for the device and ensure that in the device manager the device is correctly displayed as MTK USB Port. Launch Flash Tool, remove the checkmarks from all points except Preloader and go in mode Download. If the progress is coming but an error occurs at the end, then we are convinced that we will only flash Preloader. At the top of the Flash Tool window, next to the button Download, Press the button Format. The formatting settings window with formatting modes will open Auto and Manual. In mode Auto There are two settings, put a check from on the upper point and press OK. Formatting will begin. After the end of formatting, flash Preloader again. After a successful Preloader firmware, flash the device completely3168 or 0xc60Description of the error 3168 and its solution is an incorrect Scatter file. Use Scatter File from your device4001 or 0xfa1Description of the error 4001 and its solution change the USB port and transfer the Flash Tool to the root of the disk. Perhaps in Download Agent There is no information about the CPU/flash, so use the firmware more fresh version. An error can be hardware, for example, with a failed flash memory4008 or 0xfa8Description of the error 4008 and her decision use another version of the firmware. There is a chance that the version of the version with the older will help. The problem may be in the USB cable, in this case, replace the USB cable or port. Perhaps in the process of firmware of the villages of the battery. Charge the device and try to perform the firmware again. You can try to pull the battery out of the device and try to flash without it. Try to format the device4009 or 0xfa9Description of the error 4009 and its solution, besides reading errors in the device itself, an error can be observed in case of errors in the computer file system. For example, there is not enough space on the disk, or the file cannot be rewritten T.to. He is blocked. In order to understand the cause, you need to look at the Flash Tool log4010 or 0xfaaDescription of the error 4010 And its solution is recommended to change the version of the firmware to the 5th version, it is extremely desirable to start with version 5.1352.01 and try to flash the device through mode Firmware Upgrade. The firmware should be original for the device and contain all blocks. Try changing the firmware cable to better4032 or 0xFC0Description of the error 4032 and its decision error may occur when firming on the device with the MT6589 processor. To eliminate it, format the device through the button Format. Do not formatize if you have a device on the MT6575 or 6577 processor. After formatting, go the device with all checks by pressing the button Download. You can try reinstalling the drivers and formatting re Perform firmware if the previous attempt was unsuccessful. If nothing helped, then try changing the firmware version. It is recommended to start with version 5.1352.01. An error is related to the wrong Preloader unit. You need to find your native Preloader and flash it. If the firmware does not bring a result with a standard method, then it may be possible to flash the device through a testpolate. The appearance of this error may be facilitated by a low charge of the battery. You can try to solve the problem by isting 4 and 5 contact on the USB connector4037 or 0xFC5Description of the error 4037 and its solution, an error may occur if the line along which the program or firmware is located is located in the line of the Cyrillic alphabet or incorrect symbols, hieroglyphs. It is permissible to post the program and the firmware file only along the way that consists of Latin characters completely. An example showing incorrect file placement: C: \ Users \ User \ Desktop \ Firmware \ Tablet firmware \4050 or 0xFD2Description of the error 4050 and its solution arises if the size of the blocks in the PMT and in the Scatter file does not coincide. In general, this error is eliminated by loading of all blocks, after which the size in the PMT should change to the correct. You can try to change the version of the firmware4058 or 0xFDADescription of the error 4058 and its solution error arises if there are problems with flash memory. It is not recommended to solve the problem yourself. Error elimination options: warming up a flash-memory chip with a passing hairdryer at high temperature, about 400 degrees Celsius. You will probably have to replace the chip from the donor board, or for a new5002 or 0x138aDescription of the error5002 and its solution when setting up Flash Tool Download Agent It is necessary to choose the firmware attached to this version. The choice of other agents leads to this error5007 or 0x138FDescription of the error 5007 and its solution is a mistake usually arises if the Flash Tool program has a checkbox on the block, to which the path is incorrectly indicated, or there is no. To eliminate it, it is necessary to specify the correct path to the desired firmware block. Also, when this error occurs, use another version of the firmware, for example V5.1352.015054 or 0x13BEDescription of the error 5054 and its decision is the error in the fact that the Flash Tool program failed to get the settings of the RAM of the device. It may occur if a full reset was performed via Flash Tool. Also, an error can occur when the data is exchanged between Download Agent and device. With incorrect work of the driver, failure when transmitting can occur only if you have a Windows XP operating system with a service below the third. It is necessary to install the third service pack. In senior versions the driver USBSER.SYS I was not subjected to updates and there will be no point in reinstalling5066 or 0x13CADescription of the error 5066 and its solution is an incorrect Scatter file. It may occur if they selected Scatter from a folder with files unprepared for Flash Tool. You need to select a correve Scatter file5069 or 0x13CDDescription of the error 5069 and its decision error most likely arises due to the features of flash memory. It happens that formatting, even low.level, does not give any effect. T.e in flash memory, everything remains as it is. If done Format, then an error may appear 1037 and at the same time a message is displayed, with the need to perform Download To create sections tables. Firmware Upgrade It is not possible to perform, because of the error 1037. You can do it Download Only Preloader. Loading any other section will give an error 5069. On the version of Scatter, the size of the FAT section does not depend. You can do it Manual Format, but within UA SIZE. After formatting, an attempt to fill in any section again comes down to an error 50696045 or 0x179DDescription of the error 6045 And its solution is recommended to change the version of the firmware to the 5th version, it is extremely desirable to start with version 5.1352.016104 or 0x17D8Description of the error 6104 And its solution is recommended to change the version of the firmware to the 5th version, it is extremely desirable to start with version 5.1352.016124 or 0x17ecDescription of the error 6124 And its solution is the possibility that the error will disappear after the firmware of the native Preloader through the button Download. After that, make a firmware of the modified Recovery And full firmware6126 or 0x17eeDescription of the error 6126 And its solution is a mistake often found on the devices Huawei G610, Huawei G700, LG L60 Dual and at the moment is not solved at home. Consequences: Periodic reboot, deleted files remain in the device, when checking the memory for recording, an error occurs. The reason is that the device has a fried bootloader, which is why it is necessary to flash the broken Sec_ro for unlocking and further flashing. It all comes down to the fact that it is with the firmware Sec_ro This error arises. It is recommended to replace the memory in the service8038 or 0x1F66Description of the error 8038 and its solution to eliminate error, it is necessary to use the mode Firmware Upgrade. Attention! The firmware should be specifically for the stitched device and contain absolutely all the blocks that are usually in stock firmware8045 or 0x1F6DDescription of the error 8045 And her solution is a mistake similar to 8038, But in practice, the editing of the Scatter file does not help. To solve the problem, you can contact the service center for firming the device through the programmer. At home, sometimes the firmware option is triggered through the button Download with all installed checks. You can also try to change the version of the firmware to the 5th version, it is extremely desirable to start with version 5.1352.01. The problem can be hardware8200 or 0x2008Description of the error 8200 and its decision error occurs if you are trying to flash the device on one platform, firmware from another. For example, you have MT6577, and you are trying to flash firmware from the apparatus on MT6575. You can try to change the version of the firmware to the 5th version, it is extremely desirable to start with version 5.1352.018417 or 0x20E1Description of the error 8417 and its solution, an error may occur if the line along which the program or firmware is located is located in the line of the Cyrillic alphabet or incorrect symbols, hieroglyphs. It is permissible to post the program and the firmware file only along the way that consists of Latin characters completely. An example showing incorrect file placement: C: \ Users \ User \ Desktop \ Firmware \ Tablet firmware \Unrecognized Rom DetectedDescription of the error and its solution error arises in case of mismatch in the Scatter file and in the device. Most often happens when actions were carried out over the device on a custom outlet through a change in sections parameters in EBR. At the same time, Scatter itself usually no one changes. To eliminate the error, it is necessary to perform forced formatting with the parameters: Auto Format Flash and Format Whole Flash Except Bootloader In order to initialize the device. Do not forget to make backup in advance NVRAM, IMEI. After formatting, it is necessary to perform full firmware through DownloadThe application was not launched, since it is incorrectly configured. Repeated installation of the application can solve this problemDescription of the error and its decision to establish a package of Microsoft Visual since 2005-2008-2012-2013-2017 Redistributable Package. Also make sure that you unpacked the firmware into the root of the disk on the computer, and not try to run it from the archive
S_invalid_arguments
Description of the error 1002 and its solution is an incorrect Scatter file. For example, the Scatter file is disabled blocks Preloader and DSP_BL
S_com_port_open_fail
S_NOT_ENOCH_STORAGE_SPACE
S_NOT_ENUGH_MEMERY
S_com_port_open_fail
S_UNKNOWN_TARGET_BBCHIP
S_unsupported_ver_of_da
S_Unsupported_Operation
Chs_err
S_BROM_DOWNLOAD_DA_FAIL
S_BROM_CMD_STARTCMD_FAIL
S_BROM_CHKSUM16_MEM_RESULT_DIFF
S_BROM_CMD_JUMP_DA_FAIL
S_DA_EXT_RAM_ERROR
Nand_flash_not_found
S_DS_SOC_CHECK_FAIL
S_DA_NFB_BOOTLOODER_NOT_EXIST
S_DA_HANDSET_FAT_INFO_NOT_FOUND
S_da_emmc_flash_not_found
S_DA_SDMMC_WRITE_FAiled
S_CHIP_TYPE_NOT_MATCH
S_FT_DA_NO_RESPONSE
S_FT_DOWNLOAD_FAIL
S_FT_READBACK_FAIL
S_FT_FORMAT_FAIL
S_ft_enable_dram_fail
S_FT_FS_READ_FAIL 0XFC5
S_ft_need_download_all_fail
S_ft_get_memory_fail
S_invalid_da_file
S_FTHND_FILE_IS_NOT_LOADED_YET
S_DL_GET_DRAM_SETTINGS_FAIL
S_dl_pc_bl_invalid_gfh_file_infor
S_dl_pmt_err_no_space
S_SecURITY_SECURE_USB_DL_IMAGE_SIGN_HEADER_NOT_FUND
S_SecURITY_SECURE_USB_DL_DA_RETURN_INVALID_TYPE
S_SecURITY_INVALID_PROJECT (6124), MSP Erroe Code: 0 x 00
S_SecURITY_SECRO_HASH_INCORRECT
SP Flash Tool Error/PMT Changed for the Rom; it be downloaded
SP Flash Tool Error
SP Flash Tool Error
SP Flash Tool Error: The Load Scatter File is Invalid!

Emergency codes of refrigerator errors

Codes of errors of refrigerators that are installed in various refrigeration equipment, if you have any error on your scoreboard, look at the brand of the device installed on your equipment, after the brand you can determine the malfunction. Refrigerated controllers are usually installed in refrigerated cabinets, tables, windows, hills, shock freezing chambers, freezers, bonets, refrigerators, pharmaceutical refrigerators, milk coomers, etc.D

Advance controllers error codes

F-027 / F-031 / F-032 / F-033 / F-052 / F-053 / F-073

  • EG2. The compressor is constantly working longer than indicated in FC1.
  • EG3. Cliff in the circuit of the thermostat sensor T1.
  • EG4. Closing in the circuit of the thermostat sensor T1.
  • EG5. Cliff in the circuit of the sensor on the air cooler T2.
  • EG6. Closing in the circuit of the sensor on the air cooler T2.
  • EG7. The electric heater malfunction, the thaw ended in the interval of FP3, and not by the sensor.
  • Alg. overheating signal T1.
  • All. Smoping signal T1.
  • EG7. Cliff in the T3 sensor circuit on the second evaporator (only for F-053 / F-073).
  • EG8. Closing in the T3 sensor circuit on the second evaporator (only for F-053 / F-073).
  • All errors are discarded ESC. or automatically after eliminating the malfunction.
  • DF. is not a malfunction, indication of the activation of thawing, the glow is constant.
  • Al. The temperature below the minimum level of the C3 settings flashes along with the temperature.
  • AH. the temperature is higher than the maximum level of the C2 setting, flashes along with the temperature.
  • E1. short circuit of the sensor 1, the glow is constant.
  • E2. short circuit of the sensor 2, the glow is constant.
  • E1/E2. short circuit of sensors 1 and 2, flashes.
  • Ee. Memory error, glow constant.

AKO-14012 / Ako-14023 / Ako-14031 / Ako-14112 / Ako-14123

  • DF. Otvka is turned on.
  • Al. The temperature below the minimum set-point (C3).
  • AH. The temperature is higher than the maximum value of SET-POINT (C2) or between 99 ° C
  • E1. short circuit of the sensor, a sensor break, 110 ° C or
  • Ee. Memory error.
  • DF. The constant glow indicates the execution of the thaw, the message “df” or “Def” when hiding means that the value 2 is set for the D2 parameter.
  • Ae. alternating with temperature indication, external emergency signal (if p9 = 2).
  • An. alternating with temperature indication, sensor temperature 1 above the value set by parameter A1.
  • Al. alternating with temperature indication, sensor temperature 1 below the value set by parameter A2.
  • E1. Sensor failure 1 (sensor break, closing, temperature 110 ° C or temperature 55 ° C).
  • E2. Sensor failure 2 (sensor break, closing, temperature 110 ° C or temperature 55 ° C).
  • E5. Incorrect configuration of the sensor (see. P4, P8 parameters).
  • HER. Memory failure, messages E2 and E3 are indicated if parameter P4 is appropriately programmed, under these conditions the functioning of the equipment is the same as with the parameter P4 = 1.
  • Def. The constant glow indicates the execution of the thawing, the message “Def” when hiding, means that the value 2 is set for parameter D2.
  • E1. Constant glow, sensor malfunction 1 (sensor break, closing, temperature 110 ° C or temperature 55 ° C).
  • E2. Flogging alternately with temperature indication, sensor 2 (sensor break, closing, temperature 110 ° C or temperature 55 ° C).
  • E3. Migrating alternately with temperature indication, sensor 3 (sensor break, closing, temperature 110 ° C or temperature 55 ° C).
  • E5. constant glow, incorrect configuration of the sensor (see. parameter P4, P8).
  • Ee. constant glow, memory failure.
  • Up. blinking alternately with temperature indication, temperature value outside the nominal modes of the device and increases.
  • DN. blinking alternately with temperature indication, temperature value outside the nominal modes of the device and decreases.

Alco Controls Controller Controller Error Codes

  • E0. The refusal of the sensor at the entrance to the evaporator.
  • E1. Refusal of the sensor at the exit from the evaporator.
  • E2. The air sensor is faulty.
  • E3. Air output sensor is faulty.
  • E4. The fins of the fin is faulty.
  • LO. low temperature signal.
  • Hi. high temperature signal.
  • Mo. MOT signal, the maximum saturation temperature cannot be controlled, t.to the overheating setting is 15k.
  • EC. No cooling.
  • EH. hardware error.
  • Ed. Time error, thawing lasts longer than established.
  • E2. The air temperature sensor at the input is faulty.
  • E3. The air temperature sensor at the output is faulty.
  • E4. Faulty sensor of the ending of the latch.
  • Er. Data error data sent to the display outside the range.
  • AD. door opening signal.
  • AH. high temperature.
  • Al. low.temperature.
  • AE. Work in emergency mode, malfunctioning sensors of air temperature at the input or output.
  • DT. Continuation of time or temperature.
  • FT. Refusal to turn on the fan or temperature.
  • E0. The temperature sensor of the pipe at the input is faulty.
  • E1. The temperature sensor of the pipe temperature at the output is faulty.
  • E2. The air temperature sensor at the input is faulty.
  • E3. The air temperature sensor at the output is faulty.
  • E4. Faulty sensor of the ending of the latch.
  • Er. Data error.
  • AD. door opening signal.
  • AH. high temperature.
  • Al. low.temperature.
  • AE. Work in emergency mode, malfunctioning sensors of air temperature at the input or output.
  • Af. overheating, external systemic breakdown.
  • AO. temperature overheating, emergency work, sensor breakdown.
  • Ar. overheating, no refrigerant duct.
  • Au. overheating, valve is open for 1005 more than 2 minutes.
  • DT. Continuation of time or temperature.
  • FT. Refusal to turn on the fan or temperature.

Instruction and guide for Delonghi PAC N120 in Russian

descriptions of all possible conditions and operation situations.

It is necessary to constantly show common sense and caution when installing, working and storage

The device is made for air conditioning at home and should not be used for other purposes.Modification or any change in the characteristics of the device is a danger.The device must be installed in accordance with local standards that concern

For repair or replacement, contact the service center authorized by the manufacturer. Repair made by incompetent personnel can be a danger.This device should be used only by adults.

Do not allow the use of people (including children) with a reduced level of perception and psycho-physical capabilities or with insufficient experience and knowledge, for

the exception of cases when they are closely monitored, and they are trained in person responsible for their safety. Follow the children, make sure that the device does not serve their toy. This device must be connected to effective grounding.

Ask a qualified electrician to check the electric network.Avoid the use of power extension cords.

Before performing care, do not forget to remove the fork from the power outlet.To move the device, do not pull the power cable.

Do not install the device in the rooms in which gas, butter may be present in the air,

sulfur or near heat sources.Install the device at a distance of at least 50 cm from flammable substances (alcohol and t.P.) and from the cylinders under pressure (for example, aerosol cans).

Do not put heavy or hot items on the device.Clean the air filter weekly.Avoid using heating devices near air conditioning.In the case of transportation, the device must remain in an upright position or carefully laid

on the side. Before transportation, completely drain the water inside the device.

After transportation until the device is turned on, wait for at least one hour.When stored, do not cover the device with plastic bags.Materials used for packaging are recyclables. It is recommended to throw them into

Special containers for collecting materials of a certain type.

At the end of the service, transfer the air conditioner to a special recycling center.If the power cord is damaged, it must be replaced by the manufacturer or its service

technical service, which will avoid any risk.

Special warnings on the treatment of a coolant device

B410A. This is a cooling gas that meets EU standards in ecology.It is recommended not to make holes in the cooling circuit of the device.Informazione Ambientale: The device contains a fluoridized gas that creates a greenhouse effect and

kyotic protocol.Repair and disposal operations should only be performed by qualified specialists

(R410A, global warming potential GWP = 1975).

По табличке с характеристиками проверьте тип газа, который используется в вашем приборе.

2 control panel3 wheels4 handle5 filter 6 grate of air output from the evaporator 7 Place of storage pipe for emission

8 Air output from the capacitor

11 wall flanet12 Pipe of air production13 Adapter for the pipe (2 pcs.) 14 device for installation on the wall15 nozzle for the window16 Remote control

How to get around the error “Proven download” in SP Flash Tool

Fortunately, here we managed to provide you with a detailed method that should work for you and easily bypass the proven load on your MediaTek loading devices using Smartphone Flash tools. So, without wasting more time, let’s get down to business. Be sure to comply with all the requirements and load correctly.

Delonghi La Specialista issues

  • Skatter firmware firmware for your specific MediaTek model.
  • To connect the phone, you will need a computer with Windows OS and a USB cable.
  • PGPT [if not found in the firmware, then follow this backup WWR Guide]
  • Install MediaTek USB drives on PC.
  • Make sure the battery of your device is quite charged (more than 50%).
  • Install SP Flash Tool on your computer.
  • Install free Hex Editor Tool on a computer.
  • Take the NOTEPAD application and install it on your computer.
  • A hexadecimal calculator.

Links for downloading:

Application for limiting liability: Getdroidtips is not responsible for any problems associated with the breakdown or damage to your phone while you follow this leadership. You should know what you are doing. So do it at your own peril and risk.

  • First of all, you need to open the PGPT file at HEX Editor Tool, which you found in the firmware file or copied from a backup using WWR.
  • Now scroll down to the last section where it is displayed.
  • You can control the strings section on the right. Everything that is after the last section will be 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00.
  • So, do not forget to click at the end of the line of the last section to hold the mouse cursor (in the Hex section), or simply highlight the first line of zeros.
  • Then click the “search” in the upper menu Hexeditor Tool click “Replace”.
  • Click the Hex-Values ​​tab, insert 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 in the search field.
  • Then leave the field “Replace” empty set the direction of the “Forward” search ”click“ Replace everything ”.
  • Click OK if it is proposed to confirm.
  • Now you need to wait a bit while the Hexeditor Tool will remove all traces 00 00 00 00 00 00 00 00 00 00 00 00 00 00 after the last section.
  • Finally, press the Ctrl S keys to save the changed PGPT file, which will be overwritten as the source.
  • Then open the Scatter file through the installed NOTEPAD application [You can also use the Notepad application on your computer]
  • For example, if we assume Laf_a an error occurs.proven, but we can flash boot_a which is located just above LaF_A in the Scatter File. For reference:
  • Use the hexadecimal calculator to add the section size for LAF (which is 2800,000 because you removed part 0x) and add it to the size of the section for boot_a, which is also equal to 2800000.
  • So, in the hexadecimal calculator there will be 2800000 2800000 = 500000.
  • Then you can change the section size for boot_a from 0x2800000 to 0x5000000.
  • Remove from the Scatter file Laf_a Save the Scatter file.
  • Now return to Hexeditor Tool Open the Boot file.IMG_1064960 (obtained from File_name: in the Boot_A section Scatter) and Laf.IMG_1146880 (file name from the LAF_A section).
  • Highlight everything and copy the hexadecimal LAF contents.IMG_1146880, then scroll down boot.IMG_1064960 and insert the hexadecimal contents. This is mainly adding LAF.IMG_1146880 in the end of boot.IMG_1064960
  • Save Boot file.IMG_1064960 with an increased file size.
  • Open SP Flash Tool reboot the Scatter file to SP Flash Tool (Laf_A should no longer be on the list).
  • Now make firmware using the Format All Download return to the Scatter file in NOTEPAD and change the is_Download: false to is_download: True for pgpt.
  • Be sure to change the file name from None to the name of the pgpt file.
  • Save and reboot the Scatter file to SP Flash Tool. Now you can see the PGPT file in the list in SP Flash Tool.
  • Then you will need to flash only PGPT in the “only download” mode.
  • Now you can download the MediaTek device as a verified section broke out.
  • Now you can start firming the firmware files using SP Flash Tool.

Please pay attention:

This method can be used for firming several consistent sections (as they appear in the Scatter file), you just need to add the dimensions of all of their sections to the size of the upper flash driven, and then remove them from the Scatter file

To use the ALL Download format, the files must be attached to all displayed sections, so hide everything for which you do not have a file by installing IS_Download: FALSE for this section on the Scatter file.

Some models demand that the preferenters be marked and loaded for all operations in SP Flash Tool.

You can also follow this leadership of YouTube if you encounter any problems or do not understand what to do next.

That’s all guys. We assume that this leadership was useful for you. For further queries, you can leave a comment below.

Instructions for the control panel and air conditioners Electrolux

For the convenience of managing the working modes of climatic equipment on the housings of its internal blocks there are the main buttons, and the Electrolux air conditioner is included with it with it. It facilitates the process of changing modes and setting up the parameters of the unit, because it allows you to make all these manipulations remotely. In addition, using the remote control, you can unlock the air conditioner, change the air temperature in the room, choose a comfortable program and configure it to automatically turn on or off at a certain time.

How to use the remote control and the main characteristics of its device, the nuances of operation, description of the system design and conditions for contacting the service center describes the instructions for air conditioners Electrolux. It also contains a device for connecting the device, copies of certificates, warranty and addresses of the nearest services.

Basic lineups

Electrolux concern produces household air conditioners. Given the needs of users, the manufacturer has established the production of energy.efficient and silent devices for air conditioning and ventilation of small rooms with an area of ​​up to 50 m2. These include inverter air conditioners and units without inverter with a stationary wall type of installation of an internal block. Such installations are designed to serve rooms in private houses and apartments.

Small.sized home portable floor conditioners are monoblocks on wheels that can work for cooling and heating, but provided that the Electrolux air conditioner installation will be carried out with the arrangement of a ventilation pipe from corrugation. Such a mobile air conditioning can be installed in any room.

Household and semi-industrial cartoi split systems, which, due to their design, can serve several rooms at once. Each such multi-alert of the Electrolux split system has one powerful external unit and several (up to 8) internal ones, it can work both for heat and cold, used to serve private houses, apartments and small offices with a total area of ​​up to 200 m2.

Semi.industrial air conditioners with ceiling, channel, cassette and column type of installation of internal blocks. Such devices through the duct evenly distribute the air and are designed for use in rooms with a large accumulation of people.

Multizonal VRV and VRF systems that are able to create their own microclimate, their temperature and humidity in each individual room. To do this, they are equipped with a powerful external unit. Such models of Electrolux air conditioners are popular in private houses and in commercial installations.

The manufacturer Electrolux creates products, making Accent on its assembly quality and functionality, but does not forget about the design of the products. Thanks to this, several series of Electrolux systems are presented on the modern market:

  • Fusion. Devices that are equipped with a function of automatic defrosting. Protects the outer block from icing in the cold season.
  • Portofino. The main feature of the series is a six.speed filter, which allows the use of air conditioners in children’s rooms.
  • Monaco with a high level of energy efficiency: devices of this series produce 5 times more cold than electricity consume.
  • Nordic with a concise and original design.

As for the technological side, modern Electrolux air conditioners are equipped with advanced functions and capabilities:

  • several operating modes;
  • Electricity savings due to the function of inverter control;
  • high power;
  • increased resource;
  • multi.stage filters;
  • the presence of self.diagnosis function;
  • low noise;
  • Convenience of management.

All of the above characteristics only confirm the feasibility of choosing Electrolux air conditioners for domestic use.

Difficult situations when the help of a master is needed

In other cases, when an error message appears on the display, it is important to understand the equipment device for an independent search for a malfunction and its elimination. If there is no experience in repairing coffee machines, nor the necessary tools, it is better to use the help of specialists

Water from the tank enters the snail, where the counter with the sensor is located, pulses are considered when the pump works. When crashing the sensor, a message also appears that the hydraulic system is empty. Then the water enters the boiler, where there is a discharge valve; When the pressure is exceeded, the water is discharged into the pallet. From the boiler, the water moves to the cappuccino or the hob, which is located in the depths of the coffee machine; To check his work, disassembly is inevitable.

Thus, the breakdown can be anywhere, in the absence of experience, disassembling the coffee machine is not only accompanied by the risk of finally breaking the equipment, there is the possibility of injury, for example, when checking the pump work, it is important to disconnect the terminals, since the device is under voltage of 220 volts. By the way, an important element in any coffee machine is microswitches, the tasks of which include tracking the work of mobile mechanisms (water cranes, steam, dispensers, etc.)

Delonghi ESAM “Grounds Too Fine, Adjust Mill” (Fix/Solution)

If an error message appears on the display, and the coffee machine continues to work, as a rule, the replacement of the microswell is required, this is not within the power of the non.professional

By the way, an important element in any coffee machine is microswitches, the tasks of which include tracking the work of mobile mechanisms (water cranes, steam, dispensers, etc.). If an error message appears on the display, and the coffee machine continues to work, as a rule, the replacement of the microswell is required, this is not within the power of the non.professional.

In some models of coffee machines, not an inscription may appear, but flashing symbols indicating problems with the flow of water. Their value can be viewed in the instructions or contact the workshop.

If you could not cope with the breakdown on your own, it is important to stop in time, despite enthusiasm and an ardent desire to figure it out yourself. After all, it is not enough to disassemble the device, it is important to assemble it correctly, there are many nuances, ignorance of which will only lead to the need for expensive repairs

Ecam 650.75.MS. beautiful and high.tech

This model is an elegant coffee coffee with a touch display. The machine prepares 11 classic coffee options. In the memory of the machine, you can create 6 profiles to configure your favorite recipes. The device is equipped with a silent coffee grinder with 13 grinding levels.

  • Double cappuccino. Kapuchino is prepared automatically, Latte art beats manually.
  • Mobile management. Having downloaded the Delonghi Coffee Link application, you can control the machine from the tablet or smartphone.
  • The possibility of brewing hot chocolate.

Error 0x1: Error. (0x1)

SP Flash Tool has problems connecting to the device.

The problem with the name of the division of the pre-load on the Scatter file or SP Flash Tool has a problem with connecting to the device.

  • Change the scatter file using NOTEPAD Change the section name for all lowercase letters. [For example; Rename Preloader into Preloader or in accordance with the exact name of the file in the firmware and save the Scatter file]
  • Before connecting the phone to PC, press and hold the volume or decrease button.
  • If you get an error message when you try to format, return to the “Download” tab, set the flag for the preliminary bootloader to select it return to the “format” tab and repeat the formatting.

Error 0xc0070005: Status_da_Exceed_max_num (0xc0070005)

SP Flash Tool has problems connecting to the phone, or you set the wrong firmware.

  • If you previously pressed and held the buttons on the device, try to flash files without pressing any buttons, or vice versa.
  • Be sure to go through another firmware file or at least a converter from another firmware.

That’s all guys. We assume that this leadership was useful to you. For further queries, you can leave a comment below.

| Denial of responsibility | Contacts |RSS