Split system jax error fe

Air Conditioner Mistakes

All split-systems equipped with devices for self-diagnostics in case of malfunction give out the error code. Not always for repair of climatic equipment is necessary to interfere a craftsman. Many mistakes of wall-mounted conditioners can be fixed individually. For this purpose it is necessary just to get acquainted and to know standard malfunctions and how to correct them. We are going to discuss it in this article.

Malfunctions of domestic split systems are of very different nature. Having in their construction complicated mechanisms by their design, these devices need a special attention from the side of an owner. And if the equipment is not serviced in time, the split malfunctions will appear after a while. Malfunctions of such equipment can be numerous, but here only main, which in general can be characterized according to the following features will be pointed out:

  • Wrong choice of split system. In a case if power consumption is calculated incorrectly for the room, the compressor simply will not be able to create the temperature regime. At the same time it will be constantly in operation, overheat and, accordingly, will soon be out of order.
  • Improper installation of the equipment. The installation of climatic equipment demands the classified approach and if some requirements are violated the conditioner will work incorrectly. For example, if the height difference between the outdoor and indoor units is too big, the compressor will not be able to pump freon at the required pressure. And also if the draining pipe is not properly sloped, the condensate will not be removed as it should be.
  • Filters pollution. As a result of clogged filter elements cooling, heating and other modes will be disturbed, as well as frosting of tubes and condensate flowing on the floor may occur.
  • Refrigerant leakage from the main line. It should be noted here that loss of Freon from the system is inevitable due to evaporation and small leaks. That is why once a year it is necessary to call in specialists (if they do not have it in their schedule) to charge the system. If this procedure is not done, because of low volume of freon in the line will be low pressure. And as a consequence, tubes and the heat exchanger itself will frost up and finally the compressor will break down. But if even oil leakage or frost appeared on connections before time, it’s necessary to call specialists from service center immediately.
  • Air conditioner functioning at negative temperatures. As a rule, on the most models the manufacturer allows the operation of split-system up to.5 ˚С. At lower temperatures it is prohibited to start conditioners without an additional winter set.
  • Illiterate setting of operation modes of a conditioner. In order to regulate the processes correctly, it is necessary to read the instructions carefully.
  • Dirty exchanger. On the condenser of outdoor unit and evaporator of indoor module sometimes creates a layer of dirt, dust, small particles, which reduce the cooling capacity of the air conditioner.
  • And also it can be a weak voltage in a network. If there is not enough voltage on the line, the air conditioner will not develop enough power and will frequently shut down. At such malfunction of split system it is necessary to switch on the device through the regulator.

Error codes of Kentatsu conditioners

E1. no contact with indoor air temperature sensor; E2. no contact with evaporator temperature sensor; E3. no contact with condenser temperature sensor; E4. no contact with outdoor air temperature sensor; E5. no contact between indoor and outdoor unit; E6. warning of outdoor module overheating or freezing; E10. compressor pressure failure; E13. electricity is not supplied due to tangled wires; E14. electricity supply to wrong phase; P4. evaporator overheating; P5. condenser overheating; P7. compressor temperature level exceeded; P9. frost protection activated; P10. outlet air value is incorrect; P11. air intake pressure exceeds allowed limits; P12. current supply over voltage; ES. external module is defrosting. EU. Freon leakage.

E1. errors in non-volatile memory occurred; E2. there was a failure in the zero cycle transformation process; E3. fan incorrect rotation; E4. too high voltage applied to compressor; E5. communication with internal air temperature probe was broken; E6. communication with evaporator temperature probe was broken.

P4. evaporator of indoor module has overheated; P5. À1. there is no voltage on temperature sensors; À2. there is no connection with temperature sensor of evaporator; À3. there is no contact with temperature sensor of condenser; À6. there is malfunction of external module.

E0. malfunction of the room temperature probe; E1. malfunction of the evaporator temperature probe; E2. malfunction of the outdoor unit temperature probe; E3. no communication with outdoor unit; E4. malfunction of condenser pump; E5. errors in non-volatile memory; E6. condensate collection pan is full.

Contact our company and we will help you to solve your problem! Call us at 7 (495) 151-09-99 or email us at order@cc-online.ru

Classification of AC error codes

Fault codes of air conditioners are classified according to the conventional system of combining symbols and consist of 2-3 or more signs. They can be only figures or Latin letters, and also a combination of letters and 1-2 figures.

According to the letters it is possible to determine the place where the malfunction has occurred, and according to the number or number of blinks of the diode it is possible to determine what kind of a malfunction has occurred.

Classification of error codes:

An owner does not need to memorize all symbols and error codes of air conditioners, the more so that they are different for each brand. It is enough to pay attention to the problem in time and disconnect the unit from the network until the causes of malfunction are detected.

The air conditioner instruction manual publishes information about the codes, which will allow the owner to determine the type and difficulty of the breakdown. If the problem cannot be solved by yourself, you will have to call a service center.

Symbolic AC error codes

Symbol codes are represented as several characters, for example “”. It is not the character itself which is causing the error, but the number of characters. As a rule, symbolic error codes are displayed on the control panel.

Two-character error codes of air conditioner

Two-digit error codes use Latin letters and numbers. The first part of the code, displayed in letters, is responsible for the structural components of the split-system.

Explanation of symbols (briefly):

  • “A” and “B” are internal unit faults;
  • “E”, “H”, “F”, “J”, “L”, “P”. problems occurred in the outdoor unit;
  • “U” and “M”. these codes signal problems with the system.

The second error code is represented by digits in a sequence from 0 to 9. To determine the precise cause of the problem it is advised to study the user manual supplied with your appliance.

Three-digit air conditioner error codes

Three-digit error codes use letters and numbers, most often a combination of one alphabetic character and two numbers. There is a detailed deciphering in the enclosed manual.

Error codes of Jax air conditioners

E2. there is a malfunction in the sensor of the air temperature inside the room;

E3. malfunction of evaporator temperature sensor;

E4. malfunctions in the condenser temperature sensor;

E5. There is an error in operation of the drain pump;

E6. Protective circuit in the outdoor unit has tripped;

E7. faults in non-volatile memory;

E8. The drain pan is full.

Air conditioner error codes

fan control and main control board have no communication with each other.

Error codes of LG Art Cool air conditioners and all other LG wall mounted air conditioners:

CH1 or C1. there is a short circuit of the internal air temperature sensor or a break in the circuit;

CH2 or C2. evaporator temperature sensor short circuit or open circuit;

CH4 or C4. there was a short circuit of the temperature sensor of the capacitor or a break in the circuit;

CH5 or C5. indoor and outdoor units are connected;

CH6 or C6. inverter module circuit exceeded current;

CH8 or C8. No rotation of indoor unit fan;

CH9 or C9. No rotation of outdoor unit fan;

CH10 or C10. Split system compressor temperature control thermistor is defective (short circuit or open circuit);

CA. discharge temperature exceeds 130 degrees Celsius;

CC. EEPROM (internal non-volatile memory) error occurred;

CD. error in the inverter module;

Po. no error, system is in energy saving mode;

Lo. no error, system is in test mode.

Call for service 8(495)565-38-25 and 8(499)409-84-95. or online application

split, system, error

E0. general protection device tripped, where E is the classification code and 0 means the detail code

A0. general safety device tripped

A1. printed circuit board of indoor unit is defective

A3. Unacceptable level in drainage system

A9. electronic expansion valve defective

AH. The air filter is clogged

AJ. capacity incorrectly set (indoor unit)

C4. the temperature sensor of heat exchanger 1 is defective

# GREE-Concealed error codes # F0-F1-F2-F3-F4-F5 error codes

C5. the temperature sensor of heat exchanger 2 is defective

C6. Fan motor overloaded, sensor blocked

C7. Blind drive sensor is defective

C8. input current sensor failed

C9. Inlet air thermistor defect

CA. outlet air thermistor defect

CJ. the temperature sensor on the remote controller is out of order

CF. high pressure sensor is out of order

Call a master 8(495)565-38-25 and 8(499)409-84-95. or online application

E0. General safety device has tripped

E1. The circuit board of the outdoor unit is defective

E3. HPS (high pressure sensor) is working

E4. LPS (low pressure sensor) is working

E5. Compressor motor overloaded, overheat relay tripped

E6. Compressor motor locked out due to over current

E7. Excessive current blocked the fan motor

E9. electronic expansion valve defective

EJ. Additional protection device defective

EE. water level in drainage system is critical

EF. Heat accumulation unit defective

H1. Air temperature sensor defective

H2. Electric power supply to the system is defective

H3. high pressure sensor is defective

H4. low pressure sensor defective

H6. Compressor overloaded, system blocked

H7. fan overload, system blocked

H9. Abnormal inlet air temperature

HA. Abnormal outlet air temperature

HE. drain level sensor signal

HF. heat accumulation unit is out of order

F0. system safety devices are functioning and

F1. Safety system device is functioning

F2. Safety system device is functioning

F3. abnormally high discharge tube temperature

F6. unacceptable temperature in the heat exchanger

FA. Inadmissible discharge air pressure

Call for service 8(495)565-38-25 and 8(499)409-84-95. or by online request

FC. inadmissible suction air pressure

FE. Invalid oil pressure reading

FF. unacceptable oil level

J1. general faulty pressure sensor

J3. temperature sensor for discharge air pipe is defective

J4. Sensor faulty at the low pressure saturation point

J5. Thermistor defective on suction pipe

J6. Thermistor defective on heat exchanger (1)

J7. thermistor defective on heat exchanger (2)

J8. Thermistor defective on liquid pipe

J9. Thermistor defective on gas pipe

JH. mass temperature sensor defective

JC. suction pressure sensor defective

L3. Control box temperature too high

L4. Heat sink temperature of power transistor is too high

L5. Output DC short-term overload

L6. AC output short-term overload

L8. electronic thermal relay delay

LC. Inverter communication breakdown in outdoor unit

P0. Lack of gas (due to icing of the heat accumulation system equipment)

P1. phase failure, power supply unbalanced

P4. Power transistor (heatsink temperature sensor) failed

P5. DC current sensor defective

P6. DC/AC output sensor defective

P7. Input current (in multisystem) is too high

PJ. outdoor unit, wrong capacity setting

Call a master 8(495)565-38-25 and 8(499)409-84-95. or online application

U0. Low pressure in the system due to lack of gas

U1. Phases are incorrectly connected (need to change phases)

U2. low voltage in power supply source

U4. communication failure between the outdoor and indoor units

U5. Communication failure between remote controller and indoor unit

U6. communication failure between main and subordinate indoor units

U7. communication failure between the battery or outdoor units

U8. Communication between the remote controls is broken

UA. Improperly set parameters of outdoor unit

UH. Address (outdoor unit/interior unit) is not entered

Error codes

All air conditioners equipped with self-diagnosis and fault detection system generate an error code when a malfunction occurs. In turn, some “repairers” have only one goal. to earn as much money as possible on your trouble. In this regard, I recommend everyone to keep this material, from which you will learn how to identify the problem with the error code. If you know the cause of the problem, believe me, you can save a lot of money and maybe even fix it yourself.

CODES OF CONDITIONER ERRORS BY MARK Error codes of LG /Elgy air conditioners

air temperature sensor short circuit or break in the circuit;

evaporator temperature sensor short circuit or open circuit;

bad connection between the control panel and the wired indoor unit;

Error of float sensor of condensate level or pump (drain pump);

connection error between outdoor unit and indoor unit;

outdoor unit temperature sensor short circuit or open circuit;

switching of indoor units of multisystem to different operating modes;

HL. error similar to 04, open float sensor;

CL. the child lock is installed, you should press the Timer Min Buttons for 3 seconds to turn it on;

Po. jet cool mode set, press the jet cool button to exit

DC voltage is below 140 V (voltage after the conversion module, not the supply voltage);

low/high pressure error, pressure sensors open;

supply voltage lower/higher than normal;

PSC (inductance coil, reactor) error has occurred;

Troubleshooting Mitsubishi Ductless P8 & P6 Error Codes

discharge tube has high temperature (INV);

Discharge tube has high temperature (Cons.);

D-Pipe temperature sensor closed/broken (INV);

Outdoor temperature sensor closed/broken (INV);

condenser temperature sensor shorted/broken;

sensor on suction tube shorted/broken;

D-pipe sensor and air temperature sensor missing/broken;

Combined type power overload;

there is a connection error (main micom-sub micom);

there is a connection error (outdoor-indoor unit);

phase change, incorrect phase sequence, for systems with three-phase power supply;

EEPROM (internal non-volatile memory) error;

condenser tube (condenser) has high temperature;

radiator has high temperature (most likely it is the cooling radiator of the inverter power module);

the capacitor has a low temperature;

temperature sensor short circuit/breakage occurred;

blockage of external BLDC (commutatorless DC motor) fan;

fan control and main control board do not communicate with each other.

LG Art Cool and all other LG wall mounted air conditioner error codes:

CH1 or C1. the internal air temperature sensor is short-circuited or the circuit is open;

CH2 or C2. evaporator temperature sensor short circuit or open circuit occurred;

CH4 or C4. condenser temperature sensor short circuit or open circuit occurred;

CH5 or C5. indoor and outdoor units are connected;

CH6 or C6. inverter module circuit overcurrent;

CH8 or C8. absence of indoor unit fan rotation;

CH9 or C9. no rotation of the outdoor unit fan;

CH-10 or C10. Split compressor temperature control thermistor is defective (short circuit or breakage);

CA. discharge temperature exceeds 130 degrees Celsius;

CC. EEPROM (internal non-volatile memory) error occurred;

CD. there is an error in the inverter module;

Po. no error, the system is in power saving mode;

Lo. no error, the system is in test mode.

[collapse]Samsung / Samsung air conditioners error codes

E464. power module current overload

E466. error on the voltage of the DC board module

E221. error with outdoor temperature sensor

E251. error with temperature sensor

E468. Electric current sensor error

E237. temperature sensor winding error

E202. connection time (1 minute) has expired

E440. operation condition secession low

E441. operation condition secession high

E469. DC-Link voltage sensor error

E472. zero crossing error occurred in the AC voltage

E121. Indoor air temperature sensor shorted/broken

E122. evaporator temperature sensor shorted/broken

E154. Indoor unit fan error

E101. Connection time (1 minute) exceeded

All LEDs are blinking. EEPROM (internal non-volatile memory) error

Daikin air conditioner error codesHitachi air conditioner error codes

Error codes of Hitachi/Hitachi air conditioners of indoor unit indicator 301

If Timer is blinking at intervals of once per second, this indicates that the equipment is warming up prior to start-up and is not an error.

If Timer light flashes several times and then stops, refer to list below

01 Indoor coil temperature too high for cooling or too low for heating. Reversing valve failure.

02 Forced start of external unit. Not an error.

03 Connection error. Communication error between internal module, external module or central board.

06 Float switch activated. Check operation of pump and drainage system.

07 The condensate pump must be started manually. Drainage system switched to test mode, central board error.

split, system, error

08 Blinds not opening. Defective louver mechanism, micro switch or central board (RAF models only).

Deciphering of error codes of Haier air conditioner

Haer air conditioners are equipped with self-diagnosis system and in case of malfunction they display the following codes. The most common faults are as follows:

  • E0. problems with condensate drainage in the system;
  • E1. pressure increase in the compressor;
  • E2. The heat exchanger of the indoor unit is icing up;
  • E3. compressor pressure too low;
  • E4. compressor overheating;
  • E5. Complete compressor shutdown due to overloading;
  • E6. no connection between outdoor and indoor units;
  • E7. room module does not respond to commands from the control panel;
  • E8. indoor unit motor is overloaded.

Also, fault codes with the letter F may illuminate on the Haer air conditioner display:

  • F0. failure of room sensor;
  • F1 and F2. disconnection of indoor and outdoor unit heat exchanger sensors respectively;
  • F3. outdoor temperature sensor failure;
  • F4. disabling the thermosensor on the air supply;
  • FF. power outages.

If the Haer air conditioner blinks 6 times when the error occurs, it may indicate an F11 malfunction. It appears when the voltage in the network does not meet the standard values.

What does FE error mean on Haier air conditioner

Users of Haer air conditioners often encounter the error FE. According to the information from the manufacturer, this malfunction is deciphered as Freon Error, or Freon leak.

If there is a lack of refrigerant, the split system may be in working order, but it constantly restarts. In addition, the unit is usually not able to perform its direct functions and instead of cooling air only moves it around the room in the fan mode.

Preventive measures

Correct preventive measures can help to prevent E 6 code in the split system. When using air conditioning equipment is necessary:

  • Vacuuming and washing of the filters of the indoor unit once a month, and better every two weeks;
  • Twice a year, in spring and fall, disassemble the room module and remove contaminants from the fan and radiator;
  • Regularly drain any residual condensate from the drain pan and clean the entire drainage system with disinfectants;
  • at least once a year, clean the front module yourself or call in professionals for this purpose, especially if the unit is located at the fifth floor level or below.

It is recommended once in 2-3 years to call in service for refilling of splitsystem with freon. Over time, it is inevitable that the refrigerant will evaporate, even if the unit is in full working order. Freon escapes at an accelerated rate if inter-unit tubing connections are loosened. When losses reach 20-30% of the total, the lack of refrigerant begins to have a noticeable effect on system operation and can cause E 6 failure.