The mechanical thermostat for a water heated floor

How to connect with your own hands?

The technology of connecting the thermostat to the floor consists of these sequential actions:

  • Preparation of the place for the thermostat. Standard modifications are installed in a conventional box inside the wall, but there are also overhead models. If you purchased a recessed model, then you need under it to do a hole in the wall.
  • Positioning of the sensors. These elements are located inside the cement screed near the heating cable. Hide sensors in a special closed corrugated tube, so that concrete did not get there. From sensors it is necessary to deduce a cable to a place of fastening of the thermostat.
  • Connection to electricity. Initially, the thermostat is connected to the central power grid. They can be lead from a wall socket or similar source. Connect the cables according to the special connection diagram on the controller. It has 3 outlets, which are designed for phase, zero and ground. They must be connected in accordance with the diagram on the device frame. After that, the cables from the temperature sensor are also connected to the inputs.
  • Heating cable connection. There are two options here. If there are only two wires inside the cable, then the first pair is connected to phase and zero, and the remaining. to ground. When double wires are used, only one side of the cable is connected. For this purpose, all three wires in series are connected to the corresponding outputs. Here it is important to follow the recommendations and use the scheme provided by the manufacturers.

How to regulate the temperature of the water floor

The most common and convenient way to organize water underfloor heating is to connect the heating circuits through a manifold. This is the one that is most often used. Both pipe ends are connected to this device: one to the supply pipe and the other to the return pipe. The heating medium of the same temperature comes to the inlet of each circuit. But the length of the circuits is usually different, which leads to heating to different temperatures, and the temperature in each room should be different. So in the bathroom 25 o C or even higher is considered comfortable, and in general 20 o C or a maximum of 22 o C. Changing the temperature characteristics is only possible by changing the amount of coolant entering the circuit.

The loops of water underfloor heating are connected to a similar collector

The simplest method is to install control valves at the inlet or outlet of the collector. By turning their heads you can change the amount of heat flowing into each loop. You only have to feel the results, which is not always convenient. The scheme of actions in this case is simple, but multistage: turn up, wait some time (until the floor warms up or cools down), evaluate the result, turn up again, etc.д. Since the temperature outside is rarely stable, you often have to turn the valves.

To facilitate the task, flow meters are installed at the inlet, which makes it easier to equalize the temperature. But you also have to turn the taps manually and control the conditions by yourself.

To mechanize and automate the process special devices are used: thermostats and servo drives. Thermostats controlling and regulating devices, servo actuators. Servo actuators are installed in each circuit on the heating medium comb. Their function is by command to reduce or increase the amount of coolant flowing into the heating circuit. Thermostats for underfloor heating are usually in every room where this type of heating is installed. They are connected to the corresponding actuators and give them the control signals.

One of the schemes for controlling the temperature of the water underfloor heating

Regulators can control the temperature of the floor, or the temperature of the air. You have to keep an eye on the temperature of the air if underfloor heating is the only kind of heating. If it serves to increase comfort, it is the degree of heating of the surface under your feet and you need to check. There are models that can monitor two indicators at the same time. In this case, usually the primary criterion for evaluation is the condition of the air, and the floor temperature is secondary.

See also  Do I have to drain the water from the boiler

How the underfloor heating regulator works? On the body of the device you set the desired temperature (air or floor, depending on the model). In a deviation of one degree in one direction or another to the servomotors the command is given, by which the flow of the coolant is increased or decreased. As a result, after a while the temperature returns to normal.

The principle is simple but effective: the desired parameters are maintained steadily, but you must take into account the inertia of the system. If the pipes are laid in the screed, it takes some time for the situation to change: the entire array needs to be heated or cooled. In the case of the overhead systems, the inertia is less, and changes occur faster.

To regulate the temperature you need a collector, a thermostat and a servo

Diagram for connecting a floor heating thermostat

Diagram of connection of thermoregulators to the manifold with servomotor

This design does not require the mandatory installation of the device, such as electric floors. In the case where the boiler is not powered by electricity, there will be high financial costs for a small optimization of heating.

There is a variant of regulation in the usual manual way, focusing on subjective preferences, but only if the floor is the only heating device and the boiler does not raise the temperature above 50 degrees. But if the house (in system) there are also other heaters: radiators, a contour DHW, thermostat for a water floor to installation is obligatory.

The easiest connection scheme. installation of thermostatic head with remote sensor on the two-way valve. In this case the head, filled with a thermosensitive substance, instantly reacts to any change: when heated the substance expands, when cooled it shrinks, thereby opening or closing the supply of the heating medium.

Tip! For a large-sized house with several branches of the heating system, it is preferable to install several temperature sensors with servo drives.

Diagram of connection of the thermostat for the water floor:

Термостат для теплого пола / Floor Heating Thermostat

  • The actuator is mounted on the return comb of the manifold for underfloor heating;
  • the wires are pulled from the manifold to the controller unit equipped with an air temperature indicator;
  • The distributor box for the drive and thermostat is placed in the manifold cabinet above the combs;
  • the cable from the distribution box goes to the switchboard.

What are underfloor heating actuators? These devices, without which the temperature regulation of the liquid water coolant is not possible. Being small-sized electro-thermal devices, which open/close the supply of media, actuators function by means of a bellows. a cylinder filled with a substance that has a feature to change its volume under the influence of temperature.

Today manufacturers offer two types of actuators: open and closed. Difference in valve positioning:

  • In open designs, the valve is open until the heating/cooling signal appears (at which point it closes),
  • Normally closed. the valve is closed until a signal is given to open the valve.

The choice depends on the user’s preference, but experts advise open-type servomotors due to the fact that even in the event of a breakdown, the water in the system will continue to function and the floors will not freeze.

Important! Choosing servomotors with a 24V DC voltage supply will require the installation of an inverter.

Connection of the actuator is easy. Depending on the type of thermostat, a connection is possible:

  • in the case of a thermostat controlling a single floor heating circuit, installation is carried out using appropriate wiring;
  • If the unit is a multizone type, the wires are connected to the corresponding terminals.

Thus, the actuators perform not only the role of passing/closing the coolant, but also a protective function. The closed position signals the end of the pump, which will prolong the life of the entire equipment. the pump will not run idle, and thus the risk of failure of the system due to high pressure, will be minimized.

See also  The hot water in a two-circuit boiler is turned off

Important! In underfloor heating systems, the pumps in which the conventional solid fuel type, pump disconnection is unacceptable: the boiler will not go out anyway, and the termination of the system (the signal) threatens to rupture the entire structure. Installation of a bypass and bypass valve will avoid this situation.

Selection criteria thermoregulators for the floor heating

In order to make your heating system as effective and controllable as possible, do not neglect the expensive models of devices. In most cases, the choice of device is influenced by living conditions and the intensity of use of heating equipment.

It should be said at once. Mechanical thermostatic valves are simple and convenient. It is customary to use them in those living areas where people are constantly present. Even in a room with children, the installation of such devices is not prohibited. Appropriate protection is provided by the devices.

In those cases where there is often nobody at home, and the need for heating is constant, the best option would be to use a programmable thermostat. By setting in advance the necessary time and temperature parameters, you organize the automatic mode of operation of the floor heating. For those who are going to install a warm floor at home, when buying a thermostatic regulator should take into account a number of nuances:

  • When betting on automated devices, it is necessary to have a constant voltage in the home power grid;
  • The permissible temperature threshold of the thermostat is 60 0 C;
  • The devices are installed in two variants, with panel mounting or in a wall-mounted way. Panel mount option is used in large areas of the premises. the wall-mounted version is installed next to a socket outlet or in a control room, and is more suitable for small rooms.

The main purpose of installing a thermostat is to control the heating of the underfloor heating to achieve optimum performance. The amount of electricity consumption also depends on the functionality of the device.

The device consists of a regulating device and sensors, the information from which is taken into account when turning on and off the heat mats. Thanks to the thermostat, the temperature in the rooms is maintained even and energy consumption is minimized.

The principle of operation of the device depends on the system of underfloor heating:

  • in the water, it regulates the volume of coolant entering the system;
  • In electric ones, it regulates the current output and the operating time of the heating elements.
mechanical, thermostat, water, heated, floor

Temperature controllers are easy to use. Their mode of operation can be changed as you wish, even several times a day, without fear of breakdown or premature failure of the equipment. Minimum temperature can be set separately for each room. Some models allow you to pre-program the operation of the device at different times of the day.

Types of temperature sensors for underfloor heating systems

Operating mode of STP heating elements directly depends on the correct temperature measurement by temperature sensors. They can be built into the body of the control box or placed at a distance.

  • To determine the air temperature.
  • Infrared, which measures the floor surface heating at a distance.
  • To determine the surface temperature of the floor by contact method.
  • Combined.

The air heating sensor is usually built into the temperature controller or its mobile unit. It is used when the floor heating is the main heating system. The main requirement for its location is the presence of natural air circulation around the device.

Infrared floor temperature sensors can be integrated into the thermostat box or placed as a separate unit. The main requirement for their installation. the absence of obstacles between the sensor and the floor. The distance between the device and the analyzed surface must be at least 30 cm.

Thermal sensors of contact type have the form of a long wire with a thickening on the end. On one side, they are connected to the thermoregulator box, and on the other side, they are placed in a special long corrugated tube under the floor. This mounting feature makes it easy to replace a broken sensor with a new one.

See also  Three-way valve for underfloor heating regulation

The advantage of underfloor location is the possibility of multi-zone floor temperature control within one room. Typically, such sensors are installed when installing underfloor heating as an additional heating system.

Several sensors can be connected to a thermostat, but this scheme is mainly used as part of a complete set of equipment.

Thermostats for underfloor heating

Warranty 12 months.

Floor heating, 0 °C, 40 °C, into subnet, white

Guarantee 24 months.

Floor heating, 5 °C, 40 °C, embedded, white

Guarantee 24 months.

Floor heating, 5 °C, 40 °C, flush-mounted, white

Guarantee 24 months.

underfloor heating, 5 °C, 40 °C, flush-mounted, white

Floor heating, 5 °C, 90 °C, flush-mounted, ivory

Guarantee 12 months.

Floor heating, 5 °C, 50 °C, flush-mounted, white

Guarantee 12 months.

Floor heating, 5 °C, 45 °C, flush-mounted, white

Guarantee 12 months.

Floor heating, 0 °C, 40 °C, flush-mounted, white

Guarantee 12 months.

Floor heating, 0 °C, 40 °C, exposed installation, white

Guarantee 12 months.

Floor heating, 0 °C, 60 °C, open installation, white

Guarantee 12 months.

Floor heating, 5 °C, 35 °C, open installation, white

Guarantee 12 months.

Floor heating, 5 °C, 35 °C, open installation, white

Guarantee 12 months.

Floor heating, 15 °C, 45 °C, flush-mounted, white

mechanical, thermostat, water, heated, floor

Guarantee 12 months.

Floor heating, 15 °C, 35 °C, flush-mounted, white

Guarantee 12 months.

Floor heating, 15 °C, 35 °C, flush-mounted, white

Guarantee 12 months.

Guarantee 12 months.

underfloor heating, 5 °C, 45 °C, pre-wall, white

Guarantee 12 months.

Floor heating, 5 °C, 45 °C, flush-mounted, cream

Guarantee 12 months.

Floor heating, 5 °C, 35 °C, pre-wall, white

Guarantee 12 months.

Floor heating, 5 °C, 50 °C, flush-mounted, ivory

Guarantee 12 months.

Floor heating, 5 °C, 45 °C, flush-mounted, white

Guarantee 12 months.

underfloor heating, 5 °C, 40 °C, pre-wall installation, beige

Guarantee 12 months.

Guarantee 12 months.

The thermo-valve is the main element of your underfloor heating

The device allows you to simplify significantly, and to optimize the heating system by controlling the flow of hot and cold water into the pipeline. Thermostatic expansion valves are, therefore, the element through which the thermal fluid flows. Its functionality essentially determines the microclimate in your home.

Constructional features of the thermostatic valve:

  • The thermal head is a separate unit that is mounted on the valve stem. This part is responsible for adjusting the air temperature by changing the position of the valve bead;
  • The temperature sensor is an integral element of every thermostatic head. An oversensitive sensor collects data about the temperature in the room and transmits them to the board, where the software analyzes the data and decides whether to open or close the source of warm water.

The thermostat must be installed properly, i.e. horizontally. The same requirement applies to the valve. If you install it in a vertical position, the bellows filled with gas will fix the wrong temperature readings in the house.

  • In small rooms (kitchen, bathroom or balcony equipped for living) it does not make sense to install a sub-assemblies with a manifold. For small rooms one valve is sufficient;
  • Three-way valves are installed in large houses. Device of this type can separate the coolant with a temperature of, say, up to 40 degrees from hot water with a temperature of 60-70 degrees;
  • In apartments with two or more rooms, experts recommend installing multiple thermostatic head for two reasons: first, the temperature in each room can be different from the others, and secondly, a single thermostatic head can not perform individual calculation of water supplies for each room.

Top 10: Rating of thermostatic regulators for water underfloor heating in 2021-2022

Compiled by RatingFirmPoRemontu editorial opinion.ru. About the selection criteria. This material is subjective, not an advertisement and is not a guide to purchase. Consultation with an expert is necessary before purchase.

Rating-2021-2022 best thermoregulators for water heaters on buyers reviews: what thermoregulators are better to buy, how to choose, price comparison, buy in a reliable online store in your city.

| Denial of responsibility | Contacts |RSS